Poplawska, Magdalena’s team published research in Journal of Pharmaceutical and Biomedical Analysis in 2014-06-30 | CAS: 52548-84-2

Journal of Pharmaceutical and Biomedical Analysis published new progress about Counterfeiting. 52548-84-2 belongs to class imidazoles-derivatives, name is 1-(2-Chloroethyl)-1H-benzo[d]imidazol-2(3H)-one, and the molecular formula is C9H9ClN2O, Recommanded Product: 1-(2-Chloroethyl)-1H-benzo[d]imidazol-2(3H)-one.

Poplawska, Magdalena published the artcileDetermination of flibanserin and tadalafil in supplements for women sexual desire enhancement using high-performance liquid chromatography with tandem mass spectrometer, diode array detector and charged aerosol detector, Recommanded Product: 1-(2-Chloroethyl)-1H-benzo[d]imidazol-2(3H)-one, the main research area is flibanserin tadalafil determination counterfeit herbal supplement HPLC mass spectrometry; Adulteration; Charged aerosol detector; Counterfeit herbal supplement; Flibanserin; Unified calibration.

The new compound – flibanserin – begun to appear as a synthetic adulterant in counterfeit herbal supplements used to stimulate women sexual drive. It was detected in 2 samples submitted to the Polish National Medicines Institute for anal. The second sample contained also tadalafil. This study presents the LC method development which enables the determination of flibanserin and tadalafil. It employs 3 different detectors charged aerosol detector (CAD), diode array detector (DAD) and mass spectrometer (MS). The conditions of the elaborated method were optimized to obtain the highest sensitivity and the best resolution, especially the separation of icariin – the natural compound observed often in supplements for sexual disorders. The validation of the method proved good linearity, good accuracy and precision of the measurements recorded by all 3 detectors. Addnl., for CAD data, an alternative calculation method using a unified calibration function was presented and evaluated. It seems that this is the way to overcome the problem of non-availability of the reference standard of a target compound Flibanserin content was quantified using the data of other reference standard (tadalafil). The inaccuracy of proposed indirect determination was found to be ±3%. A statistical evaluation proved that the results obtained with all detection modes and the results calculated using a unified calibration were not significantly different (p > 0.05).

Journal of Pharmaceutical and Biomedical Analysis published new progress about Counterfeiting. 52548-84-2 belongs to class imidazoles-derivatives, name is 1-(2-Chloroethyl)-1H-benzo[d]imidazol-2(3H)-one, and the molecular formula is C9H9ClN2O, Recommanded Product: 1-(2-Chloroethyl)-1H-benzo[d]imidazol-2(3H)-one.

Referemce:
Imidazole – Wikipedia,
Imidazole | C3H4N2 – PubChem